Strengths

Xylan Coatings

bullet

A few Suggestions

We recommend the use of our approved fastener-class coating applicators, highly trained experts jn the application of pretreatments.

Further, with today's emphasis on quality (such as ISO 9000), We urge that all end users ask for and keep a record of the lot number of the Xylan coating used. This with the fastener certification document, ensures traceability.

Examples of Chemical Resistance of Xylan Coating
CHEMICAL XYLAN 1014 XYLAN 1400 XYLAN 1424
HCI (concentrated)
at room temperature(1)
Severe blisters, rust Severe blisters, rust No effect
HCI (pH 2) at room
temperature(1)
Slight marks Slight marks No effect
HCI (pH 2) 61 125°P(1) Slight marks Slight marks No effect
NaOH (5O%) at room
temperature(1)
Severe failure,
blisters
No effect No effect
NaOH (pH 12.5)(1) Severe failure,
blisters
No effect No effect
NaOH (pH 9.5) at
room temperature(1)
Slight marks No effect No effect
NaOH (pH 9.5) at 125"F(1) Slight marks Very slight marks No effect
MEK at room
temperature(1)
Slight marks Slight marks Slight marks
Toluene at room
temperature(1)
Slight marks Slight marks Slight marks
Ethylene glycol at room
temperature(1)
No effect No effect No effect
Salt spray for 1488
hours
20% red rust,
adhesion loss
!5% red rust, dense
edge blistering
<15% red rust
Kesternich 4 cycles, 2O+%, red
rust, adhesion loss
30 cycles, 1% red
rust, blistering
30 cycles, <15%
red rust
Castrol Hydraulic Fluid
at 200°F(2)
Not recommended GIoss decrease,
no loss in coating integrity
Gloss decrease,
no loss in coating integrity
W. Canning Oceanic
HK-540 at 200°F(2)
Not recommended Gloss decrease,
no loss in coating
integrity, slight
color lightening
Gloss decrease,
no loss in coating
integrity, slight color
lightening
(1) = 24-hour chemical spot tests (ASTM D730&79).
(2) = Immence tests

 

BACK  NEXT