Examples
of Chemical Resistance of Xylan Coating |
|
CHEMICAL |
XYLAN 1014 |
XYLAN 1400 |
XYLAN 1424 |
HCI
(concentrated)
at room temperature(1) |
Severe
blisters, rust |
Severe
blisters, rust |
No effect |
HCI (pH 2) at
room
temperature(1) |
Slight marks |
Slight marks |
No effect |
|
HCI (pH 2) 61
125°P(1) |
Slight marks |
Slight marks |
No effect |
NaOH (5O%) at
room
temperature(1) |
Severe failure,
blisters |
No effect |
No effect |
|
NaOH (pH
12.5)(1) |
Severe failure,
blisters |
No effect |
No effect |
NaOH (pH 9.5)
at
room temperature(1) |
Slight marks |
No effect |
No effect |
|
NaOH (pH 9.5)
at 125"F(1) |
Slight marks |
Very slight
marks |
No effect |
MEK at room
temperature(1) |
Slight marks |
Slight marks |
Slight marks |
Toluene at room
temperature(1) |
Slight marks |
Slight marks |
Slight marks |
Ethylene glycol
at room
temperature(1) |
No effect |
No effect |
No effect |
Salt spray for
1488
hours |
20% red rust,
adhesion loss |
!5% red rust,
dense
edge blistering |
<15% red rust |
|
Kesternich |
4 cycles, 2O+%,
red
rust, adhesion loss |
30 cycles, 1%
red
rust, blistering |
30 cycles, <15%
red rust |
Castrol
Hydraulic Fluid
at 200°F(2) |
Not recommended |
GIoss decrease,
no loss in coating integrity |
Gloss decrease,
no loss in coating integrity |
W. Canning
Oceanic
HK-540 at 200°F(2) |
Not recommended |
Gloss decrease,
no loss in coating
integrity, slight
color lightening |
Gloss decrease,
no loss in coating
integrity, slight color
lightening |
(1) = 24-hour
chemical spot tests (ASTM D730&79).
(2) = Immence tests |